📋 JSON metadata
{
"artifact_id": "L1-510",
"chain_block": 41552305,
"chain_hash": "0xb25b2551bc781001bdbc0c456066a6dbda2ec0862615e8c6d13eaccd12c31009",
"chain_tx_hash": "0x6eef5f3c58e7f98baff189b5095bd56113d47f055cf3e3ebc3265addd1b22f58",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 5,
"kappa": 220,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of joint (v(r, t), p(r, t)) is guaranteed within the declared Omega bounds and chamber geometry. Uniqueness holds under physiologically-consistent boundary conditions (no-slip walls, prescribed inflow/outflow, periodic-cardiac-cycle) and adequate venc/SNR; pressure recovery is conditionally unique up to a constant (Helmholtz-Hodge decomposition) \u2014 typical practice fixes pressure at one anatomical reference. Stability is moderately conditioned (kappa_eff ~ 30 after NS-regularized variational reconstruction) \u2014 venc_aliasing dominates aliasing-induced velocity errors; partial_volume_at_walls dominates wall-shear-stress bias; eddy_current_offset contributes a systematic background-velocity bias; viscosity_uncertainty contributes a scaling factor for shear-related quantities. Joint Hadamard well-posedness for the coupled MR-PC + NS forward is established by Markl et al. 2012 (foundational 4D-flow review), Stankovic et al. 2014 (clinical 4D-flow), Bertoglio-Caiazzo 2015 (NS-regularized 4D-flow inverse), Pereira et al. 2016 (assimilation), Garcia et al. 2018 (NS-regularized clinical 4D-flow), and Soulat et al. 2020 (4D-flow benchmarking).",
"secondary": "RMSE_per_velocity_component"
},
"physics_fingerprint": {
"L_DAG": 8.3,
"carrier": "radio_wave_with_blood_flow",
"difficulty_delta": 5,
"domain": "Medical Imaging",
"integration_axis": "spatial_temporal",
"noise_model": "gaussian",
"primitives": [
"L.rf_excitation",
"L.flow_encoding_gradient",
"L.gradient_echo",
"L.larmor_precession",
"L.phase_extract",
"L.navier_stokes_constraint",
"L.boundary_conditions",
"int.spatial_temporal"
],
"problem_class": "nonlinear_inverse",
"sensing_mechanism": "phase_contrast_mri_with_navier_stokes",
"solution_space": "4D_velocity_pressure_joint",
"sub_domain": "Cardiovascular blood-flow and pressure recovery via MR phase-contrast + Navier-Stokes coupling (multi-physics joint inverse)",
"title": "Cardiac 4D-flow MRI with Hemodynamic Biomechanics"
},
"size_tiers": {
"allowed_forward_operators": [
"cardiac_4dflow_joint_forward",
"cardiac_4dflow_two_step_forward",
"cardiac_4dflow_pinn_forward",
"cardiac_4dflow_with_pressure_recovery"
],
"allowed_omega_dimensions": [
"H",
"W",
"Z",
"N_cardiac_phases",
"venc_mps",
"B0_field_T",
"voxel_size_mm",
"TR_ms",
"TE_ms",
"SNR_dB",
"venc_aliasing",
"partial_volume_at_walls",
"breath_hold_motion",
"eddy_current_offset",
"segmentation_error_at_chambers",
"viscosity_uncertainty"
],
"allowed_problem_classes": [
"cardiac_4dflow_ns_regularized",
"cardiac_4dflow_aortic",
"cardiac_4dflow_pulmonary",
"cardiac_4dflow_intracardiac",
"cardiac_4dflow_with_wall_shear_stress",
"cardiac_4dflow_with_pressure_drop"
],
"center_spec": {
"epsilon_fn_center": "26.0",
"forward_operator": "cardiac_4dflow_joint_forward",
"input_format": "phase_contrast_3component_4d",
"omega": {
"B0_field_T": 3.0,
"H": 192,
"N_cardiac_phases": 25,
"SNR_dB": 24,
"TE_ms": 2.5,
"TR_ms": 5.0,
"W": 192,
"Z": 64,
"breath_hold_motion": 0.0,
"eddy_current_offset": 0.0,
"partial_volume_at_walls": 0.0,
"segmentation_error_at_chambers": 0.0,
"venc_aliasing": 0.0,
"venc_mps": 1.5,
"viscosity_uncertainty": 0.0,
"voxel_size_mm": 2.5
},
"problem_class": "cardiac_4dflow_ns_regularized"
},
"epsilon_bounds": {
"psnr_db": [
10.0,
42.0
]
},
"omega_bounds": {
"B0_field_T": [
1.5,
7.0
],
"H": [
128,
512
],
"N_cardiac_phases": [
10,
50
],
"SNR_dB": [
5.0,
38.0
],
"TE_ms": [
1.5,
5.0
],
"TR_ms": [
3.0,
10.0
],
"W": [
128,
512
],
"Z": [
32,
256
],
"breath_hold_motion": [
0.0,
0.3
],
"eddy_current_offset": [
0.0,
0.2
],
"partial_volume_at_walls": [
0.0,
0.4
],
"segmentation_error_at_chambers": [
0.0,
0.3
],
"venc_aliasing": [
0.0,
0.3
],
"venc_mps": [
0.5,
6.0
],
"viscosity_uncertainty": [
0.0,
0.3
],
"voxel_size_mm": [
1.0,
4.0
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Cardiovascular blood-flow and pressure recovery via MR phase-contrast + Navier-Stokes coupling (multi-physics joint inverse)",
"title": "Cardiac 4D-flow MRI with Hemodynamic Biomechanics"
}