📋 JSON metadata
{
"artifact_id": "L1-509",
"chain_block": 41553387,
"chain_hash": "0xedc6787d7a57c3ffbe0fcc816d4c1b47dd38ddfa2914b2392b57b48d19033e1d",
"chain_tx_hash": "0x6d485b3261bc469ae58032e3f62431adb715c465c744d975ddc8ec63b9b20fc0",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 5,
"kappa": 280,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of recovered joint state (mu_a, Z, c, rho) is guaranteed within the declared Omega bounds. Uniqueness holds under multi-illumination + multi-wavelength PA acquisition combined with US transmit-receive at adequate SNR; single-wavelength single-illumination PAUS suffers the same multiplicative non-uniqueness as single-wavelength qPAT (excluded from the spec range). Stability is moderately conditioned (kappa_eff ~ 40 after joint model-based reconstruction) \u2014 pa_us_synchronization_jitter dominates registration error; fluence_inhomogeneity dominates qPAT-class chromophore bias; acoustic_attenuation dominates US-class deep-tissue contrast; transducer_bandwidth_difference_pa_vs_us contributes a frequency-dependent reconstruction artifact (PA typically lower-frequency band 0.5-10 MHz, US higher 5-20 MHz). Joint Hadamard well-posedness for the coupled qPAT + US Born forward is established by the qPAT references (Bal-Uhlmann 2010, Bal-Ren 2011) plus the dual-mode literature: Niederhauser et al. 2005 (combined OAT/US), Beard 2011 (review), Wang LV 2008 (multiscale photoacoustic), Mehrmohammadi et al. 2013 (PA-US clinical), Park et al. 2017 (PAUS guided interventions).",
"secondary": "RMSE_per_modality"
},
"physics_fingerprint": {
"L_DAG": 9.5,
"carrier": "photon_acoustic_dual",
"difficulty_delta": 5,
"domain": "Medical Imaging",
"integration_axis": "spectral_temporal_spatial",
"noise_model": "gaussian",
"primitives": [
"L.optical_source",
"L.optical_diffusion",
"L.beer_lambert",
"L.thermoelastic_grueneisen",
"L.acoustic_wave_propagation",
"L.us_transmit_beam",
"L.us_pulse_echo",
"L.transducer_detection_dual",
"int.spectral_temporal_spatial"
],
"problem_class": "nonlinear_inverse",
"sensing_mechanism": "joint_thermoelastic_and_pulse_echo",
"solution_space": "4D_dual_contrast_functional_anatomical",
"sub_domain": "Concurrent functional + anatomical imaging via dual-contrast acquisition (multi-physics joint inverse)",
"title": "Photoacoustic-Ultrasound Dual-mode Imaging (PAUS)"
},
"size_tiers": {
"allowed_forward_operators": [
"paus_joint_forward",
"paus_alternating_pa_us_forward",
"paus_with_shared_tissue_model",
"paus_with_co_estimated_speed_of_sound"
],
"allowed_omega_dimensions": [
"H",
"W",
"Z",
"N_PA_wavelengths",
"lambda_range_nm",
"N_US_modes",
"us_center_frequency_MHz",
"us_bandwidth_MHz",
"voxel_size_mm",
"speed_of_sound_mps",
"SNR_PA_dB",
"SNR_US_dB",
"pa_us_synchronization_jitter",
"fluence_inhomogeneity",
"acoustic_speed_heterogeneity",
"acoustic_attenuation",
"transducer_bandwidth_difference_pa_vs_us",
"motion_during_acquisition"
],
"allowed_problem_classes": [
"paus_dual_contrast",
"paus_functional_only",
"paus_anatomical_guided_pa",
"paus_with_doppler",
"paus_with_shear_wave"
],
"center_spec": {
"epsilon_fn_center": "26.0",
"forward_operator": "paus_joint_forward",
"input_format": "synchronized_dual_contrast_time_resolved",
"omega": {
"H": 256,
"N_PA_wavelengths": 5,
"N_US_modes": 2,
"SNR_PA_dB": 22,
"SNR_US_dB": 28,
"W": 256,
"Z": 64,
"acoustic_attenuation": 0.0,
"acoustic_speed_heterogeneity": 0.0,
"fluence_inhomogeneity": 0.0,
"lambda_range_nm": [
700,
1064
],
"motion_during_acquisition": 0.0,
"pa_us_synchronization_jitter": 0.0,
"speed_of_sound_mps": 1500.0,
"transducer_bandwidth_difference_pa_vs_us": 0.0,
"us_bandwidth_MHz": 5.0,
"us_center_frequency_MHz": 7.5,
"voxel_size_mm": 0.2
},
"problem_class": "paus_dual_contrast"
},
"epsilon_bounds": {
"psnr_db": [
8.0,
42.0
]
},
"omega_bounds": {
"H": [
128,
512
],
"N_PA_wavelengths": [
2,
16
],
"N_US_modes": [
1,
5
],
"SNR_PA_dB": [
5,
40
],
"SNR_US_dB": [
5,
45
],
"W": [
128,
512
],
"Z": [
32,
256
],
"acoustic_attenuation": [
0.0,
0.4
],
"acoustic_speed_heterogeneity": [
0.0,
0.1
],
"fluence_inhomogeneity": [
0.0,
0.4
],
"motion_during_acquisition": [
0.0,
0.3
],
"pa_us_synchronization_jitter": [
0.0,
0.3
],
"speed_of_sound_mps": [
1400,
1600
],
"transducer_bandwidth_difference_pa_vs_us": [
0.0,
0.5
],
"us_bandwidth_MHz": [
1,
20
],
"us_center_frequency_MHz": [
1,
30
],
"voxel_size_mm": [
0.05,
1.0
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Concurrent functional + anatomical imaging via dual-contrast acquisition (multi-physics joint inverse)",
"title": "Photoacoustic-Ultrasound Dual-mode Imaging (PAUS)"
}