📋 JSON metadata
{
"artifact_id": "L1-165",
"chain_block": 41554243,
"chain_hash": "0x048b15a7a1b67344a1dbe9b1f26abb0db8f6f100361ced09a11621a64a8c9b10",
"chain_tx_hash": "0x8e4d93c8afe6fa828e687dd317430946dcaf68e7af60a5eddce68b250f3731dd",
"domain": "Scanning Probe",
"hardness_fn": {
"delta": 3,
"kappa": 260,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 2D magnetization map is guaranteed within the declared Omega bounds. Uniqueness is local rather than global (non-convex landscape); convergence depends on initialisation and priors. Stability is moderately conditioned (kappa_eff ~= 13); crosstalk_topography dominates the stability cliff; stray_field and the remaining mismatch parameters contribute higher-order bias terms. Additive gaussian thermal/electronic noise sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 3.3,
"carrier": "radio_wave",
"difficulty_delta": 3,
"domain": "Scanning Probe",
"integration_axis": "spatial",
"noise_model": "gaussian",
"primitives": [
"L.magnetic_cantilever",
"S.scan.raster",
"D.frequency_shift",
"int.spatial"
],
"problem_class": "nonlinear_inverse",
"sensing_mechanism": "magnetic_force_microscopy",
"solution_space": "2D_magnetization_map",
"sub_domain": "Magnetic cantilever probe for domain imaging",
"title": "Magnetic Force Microscopy (MFM)"
},
"size_tiers": {
"allowed_forward_operators": [
"mfm_forward"
],
"allowed_omega_dimensions": [
"H",
"W",
"pixel_nm",
"lift_height_nm",
"tip_radius_nm",
"SNR_dB",
"crosstalk_topography",
"stray_field",
"tip_magnetization_drift",
"vibration",
"crosstalk_topography",
"stray_field",
"tip_magnetization_drift",
"vibration"
],
"allowed_problem_classes": [
"mfm"
],
"center_spec": {
"epsilon_fn_center": "24.0",
"forward_operator": "mfm_forward",
"input_format": "measurement_only",
"omega": {
"H": 512,
"SNR_dB": 25,
"W": 512,
"crosstalk_topography": 0.0,
"lift_height_nm": 50,
"pixel_nm": 20,
"stray_field": 0.0,
"tip_magnetization_drift": 0.0,
"tip_radius_nm": 30,
"vibration": 0.0
},
"problem_class": "mfm"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
40.0
]
},
"omega_bounds": {
"H": 64,
"SNR_dB": [
0.0,
40.0
],
"W": 64,
"crosstalk_topography": [
0.0,
0.5
],
"lift_height_nm": [
10,
500
],
"pixel_nm": [
2,
500
],
"stray_field": [
0.0,
0.3
],
"tip_magnetization_drift": [
0.0,
0.3
],
"tip_radius_nm": [
5,
200
],
"vibration": [
0.0,
0.3
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Magnetic cantilever probe for domain imaging",
"title": "Magnetic Force Microscopy (MFM)"
}