📋 JSON metadata
{
"artifact_id": "L1-054",
"chain_block": 41553359,
"chain_hash": "0xf3a17a4cef566a2d434a04aa0a839ae9bcb8d1f11af8cd9ef236ef70d4e7d136",
"chain_tx_hash": "0x2af601a4544eeb51a482ce435bb1dca49cdf0af5b543684bd5a39809d06724ec",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 10,
"kappa": 500,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 3D material decomposition is guaranteed within the declared Omega bounds. Uniqueness is local rather than global (non-convex landscape); convergence depends on initialisation and priors. Stability is moderately conditioned (kappa_eff ~= 25); charge_sharing dominates the stability cliff; pulse_pileup and the remaining mismatch parameters contribute higher-order bias terms. Photon-shot-noise-limited (poisson counting) sets the irreducible data-fidelity floor, while TV / wavelet-sparsity / deep priors stabilise recovery at the ill-conditioned end of Omega.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 4.5,
"carrier": "x_ray",
"difficulty_delta": 10,
"domain": "Medical Imaging",
"integration_axis": "angular",
"noise_model": "shot_poisson",
"primitives": [
"L.xray_source",
"S.scan.angular",
"D.pcd_detector",
"L.spectral_decompose",
"L.backproject",
"int.angular"
],
"problem_class": "nonlinear_inverse",
"sensing_mechanism": "photon_counting_ct",
"solution_space": "3D_material_decomposition",
"sub_domain": "Energy-resolved direct-conversion CT",
"title": "Photon-Counting CT (PCCT) \u2014 spectral detector CT"
},
"size_tiers": {
"allowed_forward_operators": [
"pcct_forward"
],
"allowed_omega_dimensions": [
"H",
"W",
"Z",
"N_projections",
"N_energy_bins",
"mAs",
"pixel_mm",
"charge_sharing",
"pulse_pileup",
"beam_hardening",
"k_edge_calibration",
"charge_sharing",
"pulse_pileup",
"beam_hardening",
"k_edge_calibration"
],
"allowed_problem_classes": [
"pcct"
],
"center_spec": {
"epsilon_fn_center": "28.0",
"forward_operator": "pcct_forward",
"input_format": "measurement_only",
"omega": {
"H": 512,
"N_energy_bins": 5,
"N_projections": 720,
"W": 512,
"Z": 256,
"beam_hardening": 0.0,
"charge_sharing": 0.05,
"k_edge_calibration": 0.0,
"mAs": 100,
"pixel_mm": 0.25,
"pulse_pileup": 0.0
},
"problem_class": "pcct"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"H": 256,
"N_energy_bins": [
2,
16
],
"N_projections": [
180,
2880
],
"W": 256,
"Z": [
64,
2048
],
"beam_hardening": [
0.0,
0.3
],
"charge_sharing": [
0.0,
0.3
],
"k_edge_calibration": [
0.0,
0.1
],
"mAs": [
1,
500
],
"pixel_mm": [
0.05,
1.0
],
"pulse_pileup": [
0.0,
0.5
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Energy-resolved direct-conversion CT",
"title": "Photon-Counting CT (PCCT) \u2014 spectral detector CT"
}