📋 JSON metadata
{
"artifact_id": "L1-053",
"chain_block": 41552302,
"chain_hash": "0x676d810a8ca49f3336d11f5cfa073fd2f42f6924056eb2ec95986082c396455d",
"chain_tx_hash": "0x9e7fd79dbfb70f9a70cfaa77bc34413b1cd089fcb53a01f687ad94ea4ff1ae0f",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 3,
"kappa": 180,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 2D attenuation projection is guaranteed within the declared Omega bounds. Uniqueness holds on the measurement-supported subspace; out-of-support modes are controlled by the declared priors. Stability is well-conditioned (kappa_eff ~= 9); scatter dominates the stability cliff; optical_glare and the remaining mismatch parameters contribute higher-order bias terms. Photon-shot-noise-limited (poisson counting) sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 2.8,
"carrier": "x_ray",
"difficulty_delta": 3,
"domain": "Medical Imaging",
"integration_axis": "spatial",
"noise_model": "shot_poisson",
"primitives": [
"L.mv_xray_source",
"L.patient_attenuation",
"D.amorphous_silicon_panel",
"int.spatial"
],
"problem_class": "linear_inverse",
"sensing_mechanism": "portal_imaging_mv",
"solution_space": "2D_attenuation_projection",
"sub_domain": "MV X-ray treatment-verification imaging",
"title": "Electronic Portal Imaging (EPID)"
},
"size_tiers": {
"allowed_forward_operators": [
"portal_imaging_forward"
],
"allowed_omega_dimensions": [
"H",
"W",
"MV_energy",
"MU",
"pixel_mm",
"scatter",
"optical_glare",
"panel_saturation",
"scatter",
"optical_glare",
"panel_saturation",
"beam_energy_drift"
],
"allowed_problem_classes": [
"portal_imaging"
],
"center_spec": {
"epsilon_fn_center": "25.0",
"forward_operator": "portal_imaging_forward",
"input_format": "measurement_only",
"omega": {
"H": 1024,
"MU": 5,
"MV_energy": 6,
"W": 1024,
"optical_glare": 0.0,
"panel_saturation": 0.0,
"pixel_mm": 0.4,
"scatter": 0.2
},
"problem_class": "portal_imaging"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"H": 512,
"MU": [
0.1,
200
],
"MV_energy": [
4,
18
],
"W": 512,
"beam_energy_drift": [
0.0,
0.05
],
"optical_glare": [
0.0,
0.3
],
"panel_saturation": [
0.0,
0.3
],
"pixel_mm": [
0.1,
2.0
],
"scatter": [
0.0,
0.5
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "MV X-ray treatment-verification imaging",
"title": "Electronic Portal Imaging (EPID)"
}