📋 JSON metadata
{
"artifact_id": "L1-046",
"chain_block": 41553358,
"chain_hash": "0xd7ddf7569a81138fc26592b42a8e7866993195425b5c6627d0097f0cd9dfce57",
"chain_tx_hash": "0xa1a7462d4c71ae904d936f9b1c2e59a6dfe84bfb389b4d6dcb886eee36f5bdef",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 3,
"kappa": 200,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 2D velocity map is guaranteed within the declared Omega bounds. Uniqueness holds on the measurement-supported subspace; out-of-support modes are controlled by the declared priors. Stability is moderately conditioned (kappa_eff ~= 10); angle_correction dominates the stability cliff; wall_filter_bleedthrough and the remaining mismatch parameters contribute higher-order bias terms. Additive gaussian thermal/electronic noise sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 3.2,
"carrier": "acoustic",
"difficulty_delta": 3,
"domain": "Medical Imaging",
"integration_axis": "temporal",
"noise_model": "gaussian",
"primitives": [
"L.emit.acoustic_pulse",
"L.doppler_autocorrelation",
"int.temporal"
],
"problem_class": "linear_inverse",
"sensing_mechanism": "doppler_ultrasound",
"solution_space": "2D_velocity_map",
"sub_domain": "Blood-flow velocity via Doppler shift",
"title": "Doppler Ultrasound (color / spectral)"
},
"size_tiers": {
"allowed_forward_operators": [
"doppler_us_forward"
],
"allowed_omega_dimensions": [
"N_elements",
"PRF_kHz",
"f_MHz",
"depth_cm",
"SNR_dB",
"angle_correction",
"wall_filter_bleedthrough",
"aliasing",
"angle_correction",
"wall_filter_bleedthrough",
"aliasing",
"low_velocity_sensitivity"
],
"allowed_problem_classes": [
"doppler_us"
],
"center_spec": {
"epsilon_fn_center": "24.0",
"forward_operator": "doppler_us_forward",
"input_format": "measurement_only",
"omega": {
"N_elements": 128,
"PRF_kHz": 5,
"SNR_dB": 22,
"aliasing": 0.0,
"angle_correction": 0.0,
"depth_cm": 10,
"f_MHz": 5,
"wall_filter_bleedthrough": 0.0
},
"problem_class": "doppler_us"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"N_elements": [
32,
256
],
"PRF_kHz": [
0.5,
20
],
"SNR_dB": [
0.0,
35.0
],
"aliasing": [
0.0,
0.5
],
"angle_correction": [
0.0,
0.5
],
"depth_cm": [
1,
25
],
"f_MHz": [
1,
15
],
"low_velocity_sensitivity": [
0.0,
0.3
],
"wall_filter_bleedthrough": [
0.0,
0.3
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Blood-flow velocity via Doppler shift",
"title": "Doppler Ultrasound (color / spectral)"
}