📋 JSON metadata
{
"artifact_id": "L1-036",
"chain_block": 41553385,
"chain_hash": "0xeff332ec150d64d8ce07d27d7f3d4370132bc437f35c6726f04a0a9fb59d816d",
"chain_tx_hash": "0x1cb31a095e9536b02a750de30141eb5f77f2e96740c572822bb3960a1c2d5bba",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 3,
"kappa": 180,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 2D breast projection is guaranteed within the declared Omega bounds. Uniqueness holds on the measurement-supported subspace; out-of-support modes are controlled by the declared priors. Stability is well-conditioned (kappa_eff ~= 9); scatter dominates the stability cliff; compression_variation and the remaining mismatch parameters contribute higher-order bias terms. Photon-shot-noise-limited (poisson counting) sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 2.8,
"carrier": "x_ray",
"difficulty_delta": 3,
"domain": "Medical Imaging",
"integration_axis": "spatial",
"noise_model": "shot_poisson",
"primitives": [
"L.xray_source",
"L.compression",
"L.beer_lambert",
"int.spatial"
],
"problem_class": "linear_inverse",
"sensing_mechanism": "mammography_xray",
"solution_space": "2D_breast_projection",
"sub_domain": "Low-energy X-ray breast imaging",
"title": "Digital Mammography"
},
"size_tiers": {
"allowed_forward_operators": [
"mammography_forward"
],
"allowed_omega_dimensions": [
"H",
"W",
"kVp",
"mAs",
"pixel_um",
"scatter",
"compression_variation",
"dense_tissue_overlap",
"scatter",
"compression_variation",
"dense_tissue_overlap",
"geometric_magnification"
],
"allowed_problem_classes": [
"mammography"
],
"center_spec": {
"epsilon_fn_center": "35.0",
"forward_operator": "mammography_forward",
"input_format": "measurement_only",
"omega": {
"H": 4096,
"W": 3328,
"compression_variation": 0.0,
"dense_tissue_overlap": 0.0,
"kVp": 28,
"mAs": 75,
"pixel_um": 50,
"scatter": 0.1
},
"problem_class": "mammography"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"H": 2048,
"W": 1664,
"compression_variation": [
0.0,
0.2
],
"dense_tissue_overlap": [
0.0,
0.5
],
"geometric_magnification": [
1.0,
2.0
],
"kVp": [
22,
34
],
"mAs": [
10,
400
],
"pixel_um": [
25,
100
],
"scatter": [
0.0,
0.3
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Low-energy X-ray breast imaging",
"title": "Digital Mammography"
}