📋 JSON metadata
{
"artifact_id": "L1-033",
"chain_block": 41552300,
"chain_hash": "0xb0fee7279f4fb8f72dc0613a217ce040eac84b6bae89248905ccad2b5e60d5bb",
"chain_tx_hash": "0x7440ebfb62f7f3d37f47cf9adb30aa59e8710656d8666a930787a10907ff576c",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 5,
"kappa": 280,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 3D activity concentration is guaranteed within the declared Omega bounds. Uniqueness holds on the measurement-supported subspace; out-of-support modes are controlled by the declared priors. Stability is moderately conditioned (kappa_eff ~= 14); random_coincidences dominates the stability cliff; scatter and the remaining mismatch parameters contribute higher-order bias terms. Photon-shot-noise-limited (poisson counting) sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 3.6,
"carrier": "photon",
"difficulty_delta": 5,
"domain": "Medical Imaging",
"integration_axis": "angular",
"noise_model": "shot_poisson",
"primitives": [
"L.annihilation_511keV",
"D.coincidence_detector",
"L.backproject",
"int.angular"
],
"problem_class": "linear_inverse",
"sensing_mechanism": "pet_coincidence",
"solution_space": "3D_activity_concentration",
"sub_domain": "Coincidence-based functional PET",
"title": "Positron Emission Tomography (PET)"
},
"size_tiers": {
"allowed_forward_operators": [
"pet_forward"
],
"allowed_omega_dimensions": [
"H",
"W",
"Z",
"N_LORs",
"counts_per_LOR",
"SNR_dB",
"random_coincidences",
"scatter",
"attenuation_correction_error",
"patient_motion",
"random_coincidences",
"scatter",
"attenuation_correction_error",
"patient_motion",
"TOF_timing_jitter"
],
"allowed_problem_classes": [
"pet"
],
"center_spec": {
"epsilon_fn_center": "25.0",
"forward_operator": "pet_forward",
"input_format": "measurement_only",
"omega": {
"H": 256,
"N_LORs": 100000000,
"SNR_dB": 20,
"W": 256,
"Z": 64,
"attenuation_correction_error": 0.0,
"counts_per_LOR": 10,
"patient_motion": 0.0,
"random_coincidences": 0.1,
"scatter": 0.3
},
"problem_class": "pet"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"H": 128,
"N_LORs": [
1000000,
10000000000
],
"SNR_dB": [
0.0,
35.0
],
"TOF_timing_jitter": [
0.0,
0.5
],
"W": 128,
"Z": [
16,
512
],
"attenuation_correction_error": [
0.0,
0.3
],
"counts_per_LOR": [
0.1,
1000
],
"patient_motion": [
0.0,
0.3
],
"random_coincidences": [
0.0,
0.5
],
"scatter": [
0.0,
0.5
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Coincidence-based functional PET",
"title": "Positron Emission Tomography (PET)"
}