📋 JSON metadata
{
"artifact_id": "L1-032",
"chain_block": 41553385,
"chain_hash": "0xd9bf19b3fdc56a80e3b82a2ccb83b4a5b3824ea54bd6ad3322cec67b532a57cb",
"chain_tx_hash": "0x10936c80aee816a718793d0a1ebd44d1badaa3f7be594cf2774b8d5d81d21a6f",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 3,
"kappa": 240,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 2D acoustic reflectivity is guaranteed within the declared Omega bounds. Uniqueness holds on the measurement-supported subspace; out-of-support modes are controlled by the declared priors. Stability is moderately conditioned (kappa_eff ~= 12); acoustic_attenuation dominates the stability cliff; speed_of_sound_error and the remaining mismatch parameters contribute higher-order bias terms. Additive gaussian thermal/electronic noise sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 3.5,
"carrier": "acoustic",
"difficulty_delta": 3,
"domain": "Medical Imaging",
"integration_axis": "temporal",
"noise_model": "gaussian",
"primitives": [
"L.emit.acoustic_pulse",
"S.scan.beam",
"L.beamform",
"L.envelope_detect",
"int.temporal"
],
"problem_class": "linear_inverse",
"sensing_mechanism": "pulse_echo_ultrasound",
"solution_space": "2D_acoustic_reflectivity",
"sub_domain": "Pulse-echo diagnostic ultrasound",
"title": "Clinical B-mode Ultrasound"
},
"size_tiers": {
"allowed_forward_operators": [
"clinical_ultrasound_forward"
],
"allowed_omega_dimensions": [
"N_elements",
"N_lines",
"f_MHz",
"depth_cm",
"SNR_dB",
"acoustic_attenuation",
"speed_of_sound_error",
"shadowing",
"acoustic_attenuation",
"speed_of_sound_error",
"shadowing",
"reverberation",
"probe_pressure"
],
"allowed_problem_classes": [
"clinical_ultrasound"
],
"center_spec": {
"epsilon_fn_center": "28.0",
"forward_operator": "clinical_ultrasound_forward",
"input_format": "measurement_only",
"omega": {
"N_elements": 128,
"N_lines": 256,
"SNR_dB": 25,
"acoustic_attenuation": 0.5,
"depth_cm": 15,
"f_MHz": 5,
"shadowing": 0.0,
"speed_of_sound_error": 0.0
},
"problem_class": "clinical_ultrasound"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"N_elements": [
32,
512
],
"N_lines": [
64,
1024
],
"SNR_dB": [
0.0,
40.0
],
"acoustic_attenuation": [
0.1,
1.5
],
"depth_cm": [
1,
30
],
"f_MHz": [
1,
30
],
"probe_pressure": [
0.0,
0.3
],
"reverberation": [
0.0,
0.3
],
"shadowing": [
0.0,
0.5
],
"speed_of_sound_error": [
0.0,
0.05
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Pulse-echo diagnostic ultrasound",
"title": "Clinical B-mode Ultrasound"
}