📋 JSON metadata
{
"artifact_id": "L1-030",
"chain_block": 41553358,
"chain_hash": "0xf4c79a28699015645f56a025f6193aa5b705f56cd876ae4da68b6fef8f7b5b41",
"chain_tx_hash": "0x8b82573487585f10290305930f16657bee0817ca1216945a6624e980a874e103",
"domain": "Medical Imaging",
"hardness_fn": {
"delta": 5,
"kappa": 300,
"metric": "PSNR_dB",
"type": "epsilon_fn"
},
"initiator_dataset": [
{
"ipfs_cid": null,
"license_hash": null,
"name": "primary",
"weight": 1.0
}
],
"layer": "L1",
"observable_profile": {
"metric": "PSNR_dB",
"regime": "Existence of the recovered 3D proton density is guaranteed within the declared Omega bounds. Uniqueness holds on the measurement-supported subspace; out-of-support modes are controlled by the declared priors. Stability is moderately conditioned (kappa_eff ~= 15); B0_inhomogeneity dominates the stability cliff; motion and the remaining mismatch parameters contribute higher-order bias terms. Additive gaussian thermal/electronic noise sets the irreducible data-fidelity floor, while mild Tikhonov or analytic inversion is sufficient at the nominal Omega point.",
"secondary": "SSIM"
},
"physics_fingerprint": {
"L_DAG": 3.6,
"carrier": "radio_wave",
"difficulty_delta": 5,
"domain": "Medical Imaging",
"integration_axis": "spatial",
"noise_model": "gaussian",
"primitives": [
"L.rf_excitation",
"L.gradient_encoding",
"L.fourier_kspace",
"int.temporal"
],
"problem_class": "linear_inverse",
"sensing_mechanism": "mri_fourier_encoding",
"solution_space": "3D_proton_density",
"sub_domain": "Non-ionizing proton NMR imaging",
"title": "Magnetic Resonance Imaging (MRI) \u2014 proton-density / T1 / T2 contrast"
},
"size_tiers": {
"allowed_forward_operators": [
"mri_forward"
],
"allowed_omega_dimensions": [
"H",
"W",
"Z",
"TR_ms",
"TE_ms",
"acceleration_R",
"SNR_dB",
"B0_inhomogeneity",
"motion",
"undersampling",
"B0_inhomogeneity",
"motion",
"undersampling",
"eddy_currents",
"coil_sensitivity_drift"
],
"allowed_problem_classes": [
"mri"
],
"center_spec": {
"epsilon_fn_center": "30.0",
"forward_operator": "mri_forward",
"input_format": "measurement_only",
"omega": {
"B0_inhomogeneity": 0.0,
"H": 256,
"SNR_dB": 25,
"TE_ms": 20,
"TR_ms": 800,
"W": 256,
"Z": 128,
"acceleration_R": 1,
"motion": 0.0,
"undersampling": 1.0
},
"problem_class": "mri"
},
"epsilon_bounds": {
"psnr_db": [
5.0,
45.0
]
},
"omega_bounds": {
"B0_inhomogeneity": [
0.0,
0.3
],
"H": [
64,
1024
],
"SNR_dB": [
0.0,
40.0
],
"TE_ms": [
1,
500
],
"TR_ms": [
10,
10000
],
"W": [
64,
1024
],
"Z": [
16,
1024
],
"acceleration_R": [
1,
16
],
"coil_sensitivity_drift": [
0.0,
0.2
],
"eddy_currents": [
0.0,
0.2
],
"motion": [
0.0,
0.5
],
"undersampling": [
0.0625,
1.0
]
}
},
"staked_pwm": 0.0,
"status": "testnet",
"sub_domain": "Non-ionizing proton NMR imaging",
"title": "Magnetic Resonance Imaging (MRI) \u2014 proton-density / T1 / T2 contrast"
}